how to set up wifi stick in Solis inverter | Solis Data Logger Setup - YouTube 0:00 / 4:51 how to set up wifi stick in Solis inverter | Solis Data Logger Setup Infinite Laboratory. The next screen should say "Configuration Complete" and you may tap "OK (3/3)" to finish up the commissioning, The system needs betweenten and fifteen minutesto sendit'sfirst report in, so please wait until the system begins to show data onSolisCloudbefore leaving the site, Did you find it helpful? Step1: Select Owner or Installer for email address registration. Apologies for the long story below. Monitoring Accessory Configured But Still Won't Link? When there is a problem with any of the Solis inverters, plant operation and maintenance (O&M) professionals will appreciate that the GinlongPro APP will connect to the inverter's data logger. solis app gone off-line MATTYON Apr 14, 2022 hi all my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device" i wont get to it until tonight has anyone seen this before is it just the wifi (or has the whole system gone down) and will re-booting the system put it right These limits are designed to provide reasonable protection against harmful interference in a residential installation. Insert the datalogger to the inverter COM port. solis app gone off-line boards.ie - Now Ye're Talkin' With solis2influx.ino one can read out all inverter data (status and statistics) via Modbus and push it to InfluxDB. This process can also be used to move a Solis Data Logger from one site to another. Ginlong Solis(Stock Code: 300763.SZ) is one of the oldest and largest global string inverter specialists, that manufactures string inverters for converting DC to AC power and interacting with utility grid, which help reduce the carbon footprint of human s Shows the power supply status of the datalogger. Reliability Safety Capacity WiFi Data Logger. Interaction, Climate Change, Sustainability & View real-time data of the PV plant , and get equipment condition is controlled at anytime and anywhere. If its not broadcasting conduct this procedure - https://www.youtube.com/watch?v=nUjcDcY8-Ws - If that doesn't fix the issue of it broadcasting please contact your local Solis Service Center and RMA the WIFI Stick. Can AGL please provide some support (a guide that is user friendly in english rather than fractured english) to help me connect and gain access to my PV data. Router password is incorrect 3. solis SOL-DLS-W Data Logger Wifi Stick Introduction Data Logger Wifi Stick Is mainly used: 10 inverters 10 realize simple and Quick access to Internet. Copyright@2020 Ginlong Technologies All rights reserved, Data Logger is fairly similar to the Cellular Data Logger's process. The device must be installed away from the strong magnetic field produced by large electrical appliances such as microwave ovens, refrigerators, telephone, metal walls, etc. Hi Everyone, I got some help with the Ginlong Wifi and I have been able to set the system up and log onto the Ginlong monitoring websitebut the system says it is 'loading' but no data is shown on the site. WiFi datalogger firmware is out of date Solis Data Loggers : Solis Scan the bar code on the logger [note: a cellular logger is shown in the photo but it has the same scanning process as theWiFilogger], Tap "OK" in the top right corner once the logger serial number shows up. Did you find it helpful? Installation guide for the Solis Wifi Sitck - Nuvision Energy DHCP - Setting the IP Address - Solis Data Logger solis GPRS Stick Datalogger Instruction Manual - Manuals+ Note that all scripts use Python 3. Help us improve this article with your feedback. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If it has a good connection to the inverter do the following steps: 1. Ginlong Solis is one of the world's recognised manufacturers of string solar inverters. Step 5: Scan the SN number of the datalogger or manually input it.Note: Scan the datalogger SN, NOT the inverter SN. 5. it has come back on line, so it is obviously a connection issue, Xi Jinping must have forgot to reboot the GFW this morning, Copyright 2000- 2023 Boards Software Limited, If you have a new account but are having problems posting or verifying your account, please email us on, Hello All, This is just a friendly reminder to read the Forum Charter where you wish to post before posting in it. Log in to the page , the username is "admin" and the password is also "admin" 5. We pay our respects to their Elders past, present and emerging. Note: the SolisWiFilogger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. Start by opening yourWiFisettings and then connecting to the network that starts with "AP" - this is theWiFilogger's local network which allows you to link it to the home network. Solarman Data Loggers (4-pin only) DLS-W: WiFi only data logger; DLS-L: LAN only data logger; DLS-C: 4G cellular only data logger; Solis is no longer selling these products in the US; Our distributors likely still have stock of these products but we are not promoting them; Solarman loggers do not support remote settings changes or firmware updates If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Connect one end of an ethernet cable to LAN stick, 2: On the computer, click on the Network Connections and select the Local Connection. If its not pingable, the password is good, the signal strength is good then login to the router and check the customers firewall protections. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Monitoring Accessory Configured But Still Won't Link? S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Or directly download from APP Store or Google Play Store by searching SolisCloud. Connect one end of an ethernet cable to LAN stickand other end directly to a computer. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. Copyright@2020 Ginlong Technologies All rights reserved, If the network is not appearing, press and hold the Reset button down for 10 seconds until both NET and COM lights start to flash simultaneously, This network must be 2.4GHz as 5GHz networks are not supported. Solis WiFi Data Logger Installation Guide, Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the displayed list of plants, Tap on the plant, then tap "Device" towards the top just to the right of "Overview", Tap "Datalogger" and then left-swipe the logger with your finger - you will see "Delete" in red to the right of the device, Tap "Delete" and then tap "Delete" again when asked if you want to disassociate the datalogger, "Deleted successfully" should appear - swipe down on the page to refresh it - the deleted datalogger should disappear from the device list as shown below, The deleted datalogger can now be installed on a different site/inverter, if that was the intention, A new datalogger can be installed at this site/on this inverter now that the old one has been removed. Help us improve this article with your feedback. Data Logger into the port and be sure to secure it by tightening the black connector. If you have not already been registered on, It is highly recommended to first connect your phone to the home network that you wish to connect the, logger to. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. network that uses symbols in the password. Thanks for your help, my data logger looks like it is faulty. Required fields are marked *. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. If it does not reconnect than with your laptop/phone search for new open access point and try to connect to wifi stick, maybe it has lost settings. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. I've been in contact with the team at . I used to have problems like that all the time until I got a wifi mesh system in the house. Please follow the instructions below: Step3: Use your mobile phone to send a text message to the SIM card in the stick. AGL replaced it free of charge. Step2: Enter your account and password, then click the Register. *, We appreciate your effort and will try to fix the article. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. 1. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed Solis datalogger installation instructions APP Enso Circle Space 2.1K subscribers Subscribe 84K views 3 years ago This instructional video shows you how to setup the WIFI monitoring on your. It's probably just the datalogger that's lost connection. Solis Monitoring. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. Status indicator, easy to display working status, RESET button, one key to send data, convenient debugging, Number of connected inverters (Connect the inverters by RS485 cables. Solis Plant Offline, Please Check Devices and Netwo. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! 1. The consent submitted will only be used for data processing originating from this website. No, Modified on: Fri, Jun 10, 2022 at 11:55 AM. No-Grid - El inversor no reconoce la red. Manage Settings Continue with Recommended Cookies, Home solis solis S3-WIFI WiFi Stick Datalogger Installation Guide, WiFi Stick Datalogger QuickInstallation ManualVersion: 3.1. Internal DC Short: In the inverter head, or the wirebox? We use cookies to try and give you a better experience in Freshdesk. Solis GPRS/WiFi Data Logging Stickhi - Ginlong Note* You can use your phone, tablet or laptop. Solis Data Loggers Explained : Solis Administrators, Computer Games Moderators, Sports Moderators, https://www.boards.ie/discussion/comment/118925467#Comment_118925467, https://www.boards.ie/discussion/comment/118925665#Comment_118925665, https://www.boards.ie/discussion/2058241657/solis-app-gone-off-line, https://www.boards.ie/discussion/comment/118926624#Comment_118926624, Music Production Commercial Please follow the process for installing a new data logger. Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. 1: Connect LAN stick to operational inverter to provide power to LAN stick. Open the SolisCloud app on your phone. Solis inverter - Ginlong data logger Solar, Batteries & Technology Questions and discussion about solar, batteries, and other renewable energy technology Solis inverter - Ginlong data logger Comet 08-05-2018 09:43 PM 6 Replies 1 Like 45040 Views Hi We have just had a solar system installed.
Finesse Nails Westport, Ct,
Standard Schnauzer Rescue Uk,
Dallas Boat And Rv Show 2022,
Michael Naughton Always Sunny,
Wdrb Past News Anchors,
Articles S